COMMUNICATOR REPORTING CODES
The 4 by 2 two-digit communicator reporting code
for each event has a factory set value. These values
may be customized to fi t the specifi c installation and
the reporting requirements of the Central Station
monitoring the system.
If Point ID reporting is enabled (the factory default
setting), each sensor can report a unique alarm and
trouble code.
If Point ID is disabled, the “general” reporting codes
for each event type will be used.
Each programming function is performed with
similar keystrokes. After the system is in Setup
Mode, enter the programming step number and
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.
If the new value is accepted, a “Bing” will sound. If the new
value is not accepted, a “Double Buzz” will sound.
Making a value 0 causes the event not to
communicate to the Central Station.
NOTE: The reporting codes are fi xed for opening
and closing. A unique code is reserved for the
master and the fi ve restricted user codes. See the
Opening & Closing Reporting Codes Table.
GENERAL REPORTING CODES
Use program Steps #201 - 206 to change the
communicator reporting codes when Point ID is
disabled.
Refer to the General Reporting Codes table to view/
edit the reporting codes for each of the fi ve events.
The factory settings are listed, along with a blank
area to write in the new installation values.
STEPS #201-206
Any value from 0-99 can be programmed for each
event using these steps (enter “0” to stop an event
from reporting).
NOTE: Be careful not to duplicate codes unless the
Central Station requires specifi c codes for certain
types of events.
General Reporting Codes Table
GENERAL REPORTING CODES
STEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUES INSTALLATION 4 BY 2 VALUE
201 GENERAL FIRE REPORT CODE 0 - 99 1
202 GENERAL EMERGENCY REPORT CODE 0 - 99 2
203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3
204 GENERAL BURGLARY REPORT CODE 0 - 99 4
206 GENERAL TROUBLE REPORT CODE 0 - 99 6
ADEMCO REPORTING CODES
EVENT ALARM CODE EXTENDED CODE
SENSOR EMERGENCY E120 C0xx
CONSOLE EMERGENCY E120 C026
SENSOR FIRE E111 C0xx
CONSOLE FIRE E110 C025
BURGLARY ALARM E130 C0xx
SILENT PANIC E122 C0xx
FORCE ARM E574 C000
DURESS E121 C000
CANCEL E406 C000
SENSOR LOW BATTERY E384 C0xx
SENSOR STATUS TROUBLE E381 C0xx
CONSOLE LOW BATTERY E302 C000
CONSOLE BATTERY RESTORE R302 C000
2-WAY AUDIO E606 C000
xx = SENSOR NUMBER IN EXTENDED REPORT
HOME
TEST
= PROGRAM
= REMOVE
AWAY
= STORE
0 - 99 FOR GENERAL
ALARM REPORTING CODE
PROGRAMMING STEPS
#201 TO #206
PROGRAM
STORE PROGRAM
2
ABC