Page 1 - SECURITY CONSOLE

SUPERVISED WIRELESSSECURITY CONSOLEUSA & Canada (800) 421-1587 & (800) 392-0123(760) 438-7000 - Toll Free FAX (800) 468-1340www.linearcorp.com

Page 2 - INTRODUCTION

8CONSOLE LOCATION✎ NOTE: Wireless sensor signals must be able to reach the Console.✔ Try to centrally locate the Console.✔ Keep Console away from l

Page 3 - TABLE OF CONTENTS

9EXTERNAL CONSOLE SPEAKER CONNECTION✦ An external console speaker sounds system tones and alerts occupants with a loud siren during alarm.✦ With the

Page 4 - † NOTE: These accessories

10TELEPHONE LINE CONNECTION ✦ Connect the Console to the telephone line if the system is monitored, requires 2-way audio, or requires telephone remot

Page 5

11CONSOLE POWER CONNECTION✦ The Console is powered by a low voltage plug-in transformer.✦ Use up to 25 feet of 20 AWG or larger two-conductor wire t

Page 6 - Console

12✦ In a new installation, when power is fi rst applied the system's master user code is “1234”.CREATE THE MASTER USER CODE✎ NOTE: Local program

Page 7 - 3. TYPICAL SYSTEM SENSORS

13PROGRAMMING DIFFERENT SENSOR TYPES✦ Follow the instructions on the previous page to select a sensor number to program the sensor into.✎ NOTE: A se

Page 8 - 4. CONSOLE FEATURES

14✦ Each accessory sensor is packaged with its own set of installation instructions specifi c to the model of sensor.✦ Refer to the sensor's ins

Page 9

15DXS-31 & DXS-32 DOOR/WINDOW SENSORS✦ The DXS-31 and DXS-32 sensors can be used to monitor doors, windows, cabinets, crawl space doors, gates, f

Page 10 - 5. CONSOLE INSTALLATION

16✦ The Console can be customized for the specifi c installation.✦ A label sheet with sensor location names is provided with the Console.✦ Labeling

Page 11 - TERMINAL

17OFF MODE✦ Use this mode to disarm the burglary portion of the system.✦ Switching to Off Mode stops any alarms in progress.✦ The 24-hour functions

Page 12 - Programmable Options

CONGRATULATIONS for selecting Linear’s DVS-1200 Security System. The DVS-1200 Console incorporates many advanced and sophisticated features. The syste

Page 13 - TO AC POWER TERMINALS

18HOME MODE✦ Use this mode when sleeping or when anyone is staying inside.✦ Home Mode causes an instant alarm when any perimeter sensor is triggered

Page 14 - 6. BASIC CONSOLE PROGRAMMING

19AWAY MODE✦ Use this mode when no one will be staying home.✦ Each burglary sensor can trigger the siren once per arming period.✦ Away Mode causes

Page 15 - SEND SIGNAL WITH LEFT BUTTON

20TEST MODE✦ Even though this is a self-monitoring supervised system, the National Burglar and Fire Alarm Association recommends that all security sy

Page 16 - 7. BASIC SENSOR INSTALLATION

21✦ The DVS-1200 Console is a self-monitoring supervised wireless system.✦ If the Console detects a problem with any of the supervised system sensor

Page 17 - OPTION JUMPER

22✦ Adding additional sensors will increase the protection provided by the system.✦ All ground-level perimeter openings and accessible upper-story o

Page 18 - 8. CUSTOMIZING THE CONSOLE

23MAKING A SENSOR A 24-HOUR DOOR CHIME✦ Sensors can be programmed to cause the Console to chime any time they're activated.✦ Chime-only sensors

Page 19 - 9. CONSOLE OPERATING MODES

24MAKING A SENSOR PERFORM A DIFFERENT FUNCTION✦ Sensors can be reprogrammed to perform different sensor functions.✦ The sensor must have already bee

Page 20 - SECURE EXIT

25✦ To perform any of the advanced programming steps, the Console must be in the Setup Mode.✦ Each programming function is performed with similar ke

Page 21 - QUICK ARM

26CHANGING A SENSORS SUPERVISION✦ When a sensor is programmed, the Console automatically recognizes it as supervised or non-supervised.✦ The Console

Page 22 - TEST MODE

27FIRE SIREN TIME✦ The factory-set fi re siren time is fi ve minutes (UL installation maximum).STEP #32 The fi re siren time can be adjusted from one t

Page 23 - (PRESS FOR 1 SECOND)

1TABLE OF CONTENTS1. THE DVS-1200 SECURITY SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2CONSOLE . . . . . .

Page 24 - 11. CUSTOMIZING THE SYSTEM

28SILENT BURGLARY ALARMS✦ The factory setting causes audible burglary alarms.STEP #63 The Console can be programmed for silent burglary alarms using

Page 25

29AUTOMATION OUTPUT MODE DURING ALARM✦ The factory setting causes the Automation Output to fl ash if it is programmed to activate during or after an a

Page 26 - SENSOR FUNCTION TABLE

30AUTOMATION OUTPUT WHILE ARMED✦ The factory setting causes the Console's Automation Output to activate when pressing the key, or when it'

Page 27 - 12. ADVANCED PROGRAMMING

31ADDING ADDITIONAL USER CODES✦ The Console can be programmed with fi ve restricted user codes and one page alert user code.✦ The restricted user cod

Page 28

32✦ To perform any of the communicator programming steps, the Console must be in the Setup Mode.✦ Each programming function is performed with simila

Page 29

33GENERAL COMMUNICATOR OPTIONSCOMMUNICATOR ENABLE✦ The factory setting for the Console disables the communicator. If the system is going to be a non-

Page 30

34CALL LIMITER✦ The factory setting for the call limiter is OFF. This allows the communicator to report burglary alarms, once for each sensor, as man

Page 31

35COMMUNICATOR REPORTING OPTIONSREPORTING FORMAT✦ The factory setting causes the communicator to report using the 4 BY 2 FORMAT. This format allows f

Page 32 - MASTER USER CODE:

36ACCOUNT NUMBER✦ The account number entered for the communicator must be 4-digits long.✦ The factory setting for the account number is 0000.STEP #8

Page 33 - #92 TO 98

37REPORT CONSOLE TROUBLE✦ The factory setting does not report Console trouble events to the Central Station.STEP #108 The communicator can be progra

Page 34 - 13. COMMUNICATOR PROGRAMMING

2CONSOLEThe DVS-1200 Console is the heart of the system. It monitors all of the system’s wireless sensors and controls the alarm sirens.The Console co

Page 35

38COMMUNICATOR REPORTING CODES✦ The 4 by 2 two-digit communicator reporting code for each event has a factory set value. These values may be customiz

Page 36

39SYSTEM REPORTING CODES✦ Refer to the System Reporting Codes table to view/edit the reporting codes for the keypad FIRE and EMERGENCY buttons and fo

Page 37

404 BY 2 FORMAT POINT ID REPORTING CODES4 BY 2 FORMAT POINT ID ALARM REPORT CODES✦ Refer to the 4 by 2 Format Point ID Reporting Code table to view/e

Page 38

414 BY 2 FORMAT POINT ID REPORTING CODESSTEP # PROGRAMMING FUNCTION POSSIBLE 4 BY 2 VALUES FACTORY 4 BY 2 VALUE INSTALLATION 4 BY 2 VALUE210 SENSOR 1

Page 39

LINEAR LIMITED WARRANTYThis Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only

Page 40 - = REMOVE

3DOOR/WINDOW SENSORSThe DXS-31 and DXS-32 sensors monitor doors and windows. They send radio signals to the Console. One type of signal is sent when t

Page 41

4EXAMPLE SYSTEM✦ The example shows a typical DVS-1200 system.✦ Any or all of the accessories shown can be used.✦ A total of 12 sensors can be used

Page 42

5DOOR/WINDOW SENSOR✦ Sensor mounts on door or window with adjacent magnet.✦ Opening door or window moves magnet away, triggering sensor.✦ Pressing

Page 43

61 24-HOUR BUTTONS★ Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message to a central monitoring station through the digita

Page 44 - 14. IMPORTANT INFORMATION

710 AUXILIARY FUSE★ Type 2AG, 1-amp fuse.★ Protects the external relay output when used with wet contacts (12 VDC switched out).★ Fuse will blow wh