TEST MODE
Even though this is a self-monitoring supervised
system, the National Burglar and Fire Alarm
Association recommends that all security systems
should be tested manually on a regular basis.
1. The Console must be in Off Mode before switching
to Test Mode.
2. Switch the Console into Test Mode by entering a
user code and pressing TEST.
When the system is switched to the Test Mode, the Console
will sound a “Gong” and four “Beeps”.
3. Holding down the TEST button in Test Mode will light
all of the Console’s indicators.
The sensor status indicators will fl ash for each sensor
programmed into the Console.
4. Go to each sensor and press its test button or open
and close the protected opening.
5. To test the wireless keypad, press the wireless
keypad’s
key.
The Console will make a “Bing” sound as each sensor is
tested, followed by 1-3 beeps indicating signal strength with
3 beeps being the strongest signal.
As each sensor is tested, the sensor status indicator for the
sensor will stop fl ashing and return to showing the current
status of the sensor.
6. Continue testing until there are no fl ashing sensor
status indicators.
SENSOR OPERATION IN EACH CONSOLE MODE
SENSOR TYPE OFF MODE CHIME MODE HOME MODE AWAY MODE
AUTOMATION ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT
EMERGENCY ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM
PANIC ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
FIRE ARMED 24-HOURS - TRIGGERS FIRE ALARM
PERIMETER DEACTIVATED CHIME INSTANT BURGLARY ALARM
EXIT/ENTRY DEACTIVATED CHIME DELAYED BURGLARY ALARM
INTERIOR DEACTIVATED DEACTIVATED DEACTIVATED
INSTANT BURGLARY ALARM UNLESS
ACTIVATED DURING AN ENTRY
DELAY, THEN IT IS DELAYED
CHIME CHIME
2-BUTTON ARM/DISARM (LEFT)
2-BUTTON AUTOMATION (RIGHT)
EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
2-BUTTON ARM (LEFT)
2-BUTTON DISARM (RIGHT)
EMERGENCY (BOTH BUTTONS)
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
ENVIRONMENTAL ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY
INTERIOR HOME DEACTIVATED DEACTIVATED INSTANT BURGLARY ALARM
NOTE: If the Console is left unattended in Test
Mode, it will automatically switch back to Off Mode
after three minutes.
When directly connecting (without a telephone
line) to the DVS-1200 with the RA-2400 remote
access software (Version 1.3 or later), press the
EMERGENCY key while in Test Mode to cause the
Console to connect to the modem.
CAN BE HOME MODE USING PROGRAMMING STEP 50
CAN BE CHIME MODE USING PROGRAMMING STEP 51
Console Zone Table
START IN OFF
YOUR
USER
CODE
DONE
1 GONG
& 4 BEEPS
(OPTIONAL)
TEST MODE
TEST
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 43 44

Comments to this Manuals

No comments