Linear DVS-1200 User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
35
COMMUNICATOR REPORTING OPTIONS
REPORTING FORMAT
The factory setting causes the communicator to
report using the 4 BY 2 FORMAT. This format allows
four-digit account numbers from 0000 to 9999 and
provides two-digit alarm codes.
STEP #105 ADEMCO CONTACT ID can be chosen as a reporting
format using this step. This format allows 4-digit
account numbers from 0000 to 9999 and provides
verbose report descriptions with Ademco Contact ID
compatible Central Stations.
CALL ROUTING
The communicator can be programmed with three
telephone numbers; primary, secondary, and
supervisory.
The factory setting for the communicator is to
route all calls to the primary telephone number. If
communication is unsuccessful after fi ve attempts
to the primary number, the secondary number
will be dialed for an additional fi ve attempts. If
the secondary number cannot be reached, the
communicator will “sleep” for fi ve minutes before
starting the call process over again. A total of four
sleep cycles (50 call attempts) can occur before the
communicator stops calling.
STEP #86 The communicator can be programmed to report
supervisory events (low battery, trouble, AC failure,
etc.) to the supervisory telephone number instead
of the primary or secondary telephone numbers
using this step.
Communicator Reporting Option Table
CAUTION: If the page alert user code feature
is going to be used, the supervisory number is
reserved for the pager number. DO NOT SET THE
CALL ROUTING OPTION TO “1”.
NOTE: To disable supervisory reports, set call
routing option to “1” and remove the supervisory
telephone number.
NOTE: Do not program the primary and secondary
telephone numbers the same. See the FCC
Telephone Rules and Regulations on the rear
cover of this manual.
COMMUNICATOR REPORTING OPTIONS
STEP
#
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
86 CALL ROUTING
0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER
1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND ALL
OTHERS TO SUPERVISORY NUMBER
0
88 ACCOUNT NUMBER 4 DIGITS EMPTY
89 PRIMARY PHONE NUMBER UP TO 20 DIGITS EMPTY
90 SECONDARY PHONE NUMBER UP TO 20 DIGITS EMPTY
91 SUPERVISORY/PAGER PHONE NUMBER UP TO 20 DIGITS EMPTY
PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY
THE [FIRE] KEY INSERTS A 5-SECOND DELAY
FOR ALL PHONE NUMBERS ⇒ ⇒ ⇒ THE [CHIME] KEY INSERTS A
*
THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER
105 REPORTING FORMAT 0 = 4 BY 2; 1 = ADEMCO 0
108 REPORT SYSTEM TROUBLE 0 = NO; 1 = YES 0
110 REPORT FORCE ARMING 0 = NO; 1 = YES 0
111 OPEN/CLOSE 0 = NO; 1 = YES; 2 = MASTER PAC ONLY 0
113 POINT ID REPORTING FOR 4 BY 2 FORMAT 0 = NO; 1 = YES 1
0
5
JKL
HOME
AWAY
0 FOR 4 BY 2
1 FOR ADEMCO CONTACT ID
PROGRAMMING STEP #105
PROGRAM
STORE PROGRAM
1
8
TUV
6
MNO
HOME
AWAY
PROGRAMMING STEP #86
PROGRAM
STORE PROGRAM
0 FOR ALL TO PRIMARY/SECONDARY
1 FOR ALARMS ONLY TO
PRIMARY/SECONDARY
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 43 44

Comments to this Manuals

No comments