12. ADVANCED PROGRAMMING
To perform any of the advanced programming
steps, the Console must be in the Setup Mode.
Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press the [
HOME
] key (HOME = program), enter
the new value, and press the [
AWAY
] key
(AWAY = store). Follow the figures next to the
programming steps.
SETUP MODE
Start with the Console in Test Mode (Setup
Mode cannot be reached from any other mode).
From Test Mode, enter the master user code
then press [
TEST
].
NOTE: Only the master user code can be used to
put the Console into the Setup Mode. The
restricted user codes cannot access Setup Mode.
A “gong” and five “beeps” will sound, signaling
that the Console is in Setup Mode.
Hold the [
OFF
] key for three seconds when you
want to exit Setup Mode.
NOTE: If the Console is left unattended in Setup
Mode, it will automatically switch back to Off Mode
after three minutes.
CONSOLE PROGRAMMING OPTIONS
STEP # PROGRAMMING FUNCTION POSSIBLE VALUES FACTORY VALUE INSTALLATION VALUE
25 ENTRY DELAY 20-255 SECONDS 30
26 EXIT DELAY 20-255 SECONDS 60
30 BURGLARY SIREN TIME 1-30 MINUTES 5
31 EMERGENCY SIREN TIME 1-30 MINUTES 5
32 FIRE SIREN TIME 1-30 MINUTES 5
40 AUTOMATION OUTPUT TIME 0-2500 SECONDS (0 = TOGGLE ON/OFF) 0
50 REMOTE ARMING MODE 2 = HOME MODE; 3 = AWAY MODE 3
51 REMOTE DISARMING MODE 0 = OFF MODE; 1 = CHIME MODE 0
61 ENTRY DELAY BEEPS 0 = OFF; 1 = ON 1
62 EXIT DELAY BEEPS 0 = OFF; 1 = ON 1
63 SILENT BURGLARY ALARM 0 = AUDIBLE; 1 = SILENT 0
64 SILENT EMERGENCY ALARM 0 = AUDIBLE; 1 = SILENT 0
65 QUICK ARMING 0 = OFF; 1 = ON 1
66 AUTO RESTORE 0 = OFF; 1 = ON 1
67 AUTO BYPASS 0 = OFF; 1 = ON 0
68 AUTOMATION MODE DURING ALARM
0 = FLASH (ENABLED BY FUNCTION 72)
1 = STEADY (ENABLED BY FUNCTION 72)
0
69 AUTOMATION BING TONE
0 = NO BINGS
1 = BINGS
1
70 REMOTE ARM/DISARM CHIRP
0 = NO CHIRPS
1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED)
1
71 AUTOMATION FLASHES AFTER ALARM
0 = STANDARD
1 = FLASHING AFTER ALARM
0
72 AUTOMATION ACTIVE DURING ALARM
0 = STANDARD
1 = AUTOMATION ACTIVE DURING ALARM
(FLASH OR STEADY PROGRAMMED BY FUNCTION 68)
0
73 AUTOMATION ON WHILE ARMED
0 = STANDARD
1 = ON WHILE ARMED
0
74 AUTOMATION ON DURING EXIT/ENTRY
0 = STANDARD
1 = ON DURING EXIT/ENTRY DELAYS
0
75 AUTOMATION POLARITY 0 = + WHEN OFF; 1 = + WHEN ON 1
87 REMOTE ACCESS PASSWORD 6 DIGITS 987654
92 DURESS CODE 1-5 DIGITS REMOVED
93 RESTRICTED USER CODE #1 1-5 DIGITS REMOVED
94 RESTRICTED USER CODE #2 1-5 DIGITS REMOVED
95 RESTRICTED USER CODE #3 1-5 DIGITS REMOVED
96 RESTRICTED USER CODE #4 1-5 DIGITS REMOVED
97 RESTRICTED USER CODE #5 1-5 DIGITS REMOVED
98 PAGE ALERT USER CODE 1-5 DIGITS REMOVED
99 MASTER USER CODE 1-5 DIGITS 1234
Console Programming Table
HOME
TEST
= PROGRAM
= REMOVE
AWAY
= STORE
25
Page view 26