DXS-80
WIRELESS
CARBON
MONOXIDE
ALARM
Installation
Instructions
PRODUCT DESCRIPTION
The DXS-80 is a carbon monoxide (CO) alarm with a built-in transmitter
designed for use with Linear’s DXS and DX Format receivers. The
detector gives warning to alert against both the acute and chronic
effects of CO poisoning. When carbon monoxide is detected, the alarm
sounds a loud local alarm. When the local alarm sounds, the built-in
transmitter sends a digitally coded wireless signal to its companion
receiver every 20 seconds until the air has cleared and the detector
is restored.
The local alarm can be silenced once by pressing the TEST/RESET
button. The transmitter will continue to send an alarm signal every 20
seconds. After 7 minutes, the alarm will sound again if there is still an
unsafe CO concentration level. The reset function can be used only
once for each alarm occurrence.
The DXS transmitters are precoded at the factory to one of over a
million possible unique system codes, so no field coding is required.
Receivers must be programmed to the transmitter’s code before
system testing and operation. Refer to the receiver’s instructions for
details on programming.
The unit is powered by one 3-volt lithium battery. The battery is supplied
with the transmitter and can power the unit for more than one year. If the
battery voltage drops below a preset level the alarm will sound a low
battery chirp every 45 seconds and a low battery signal will be sent to
the receiver (some receivers can report low battery, others cannot).
When the detector reaches the end of its serviceable life (after about 6
years) a permanent trouble condition will occur and cannot be reset.
Maintenance: Occasionally clean the outside casing with a cloth.
Ensure that the holes on the front of the alarm are not blocked with dirt
and dust. Do not paint, and do not use cleaning agents, bleach, or
polish on the detector.
DXS-80 FEATURES
SELECT PROPER LOCATION REMOVE MOUNTING PLATE REMOVE BATTERY TAB
INSTALL MOUNTING PLATE PROGRAM RECEIVER MOUNT ALARM ON PLATE
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
BY
PRINTERS INSTRUCTIONS
INSTR,INSTL,DXS-80 - P/N: 227112 D - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2
TEST/RESET
BUTTON
ALARM
SOUNDER
CARBON
MONOXIDE
ALARM
MOUNTING
PLATE
MOUNTING
SCREWS &
ANCHORS
ALARM SIGNALS
NORMAL
OPERATION
GREEN LED FLASHES EVERY 10 SECONDS.
ALARM
SIGNAL
A REPEATING PATTERN OF FOUR SHORT BEEPS AND
5 SECOND SILENCE. THE RED LED WILL FLASH ONCE
PER SECOND.
TROUBLE
SIGNAL
DETECTOR SELF-TESTS EVERY 5 SECONDS. IF A FAULT
IS DETECTED, RED LED WILL BLINK ONCE EVERY
5 SECONDS AND DETECTOR WILL BEEP EVERY 45
SECONDS.
LOW BATTERY
SIGNAL
RED LED BLINKS EVERY 45 SECONDS.
REPLACE THE BATTERY WHEN THIS SIGNAL OCCURS.
END-OF-LIFE
SIGNAL
RED LED WILL BLINK ONCE EVERY 10 SECONDS AND
DETECTOR WILL BEEP EVERY 45 SECONDS. IN THIS
CONDITION, THE DETECTOR REQUIRES IMMEDIATE
REPLACEMENT.
Family Room
Bedroom
Kitchen
Dining
Room
Living Room
Bedroom
Bedroom
= Carbon Monoxide
alarm location
Bedroom
BedroomBedroom
Living
Room
Basement
Kitchen
Garage
= Carbon Monoxide alarm
location for multi-level
residence
Inside wall location
Height 5' - 6' from floor
= Carbon Monoxide alarm
mounting location
FIGURE 1. RECOMMENDED
CO ALARM PLACEMENT FOR
SINGLE FLOOR RESIDENCE
FIGURE 2. RECOMMENDED
CO ALARM PLACEMENT FOR
MULTI-LEVEL RESIDENCE
FIGURE 3. RECOMMENDED
CO ALARM MOUNTING
LOCATION IS 5 TO 6 FEET
FROM FLOOR
REFER TO SECTION
NUMBER 5 ON THE
REAR OF THESE
INSTRUCTIONS FOR
IMPORTANT MOUNTING
DETAILS
PRESS UNTIL ALARM
BEEPS THEN RELEASE
TEST BUTTON TO
SEND SIGNAL
REFER TO RECEIVER'S INSTRUCTIONS TO
PREPARE RECEIVER TO ACCEPT THE
TRANSMITTER'S CODE
A TEST SIGNAL WILL BE SENT A
FEW SECONDS AFTER THE
SWITCH IS RELEASED
ALIGN TAB IN PLATE WITH
NOTCH IN COVER
TWIST CO ALARM CLOCKWISE TO
LOCK ONTO MOUNTING PLATE
®
LISTED
SIGNALING
TWIST MOUNTING
PLATE TO UNLOCK
REMOVE
MOUNTING
PLATE
PULL TO CONNECT
BATTERIES
REMOVE
BATTERY TAB
TO APPLY
POWER
3-VOLT LITHIUM BATTERY - TYPES: DURACELL DL123A,
PANASONIC CR123A, SANYO CR123A, ADEMCO 466.
AVAILABLE AT LOCAL RETAILERS AND INTERNET
SUPPLIERS.
NOTE:
USE ONLY THESE SPECIFIC
BATTERY MODELS.
NOTE: ON POWER-UP THE RED AND
GREEN LEDS WILL BLINK 4 TIMES,
15 SECONDS APART WHILE
THE ALARM INITIALIZES.
SCREW
ANCHORS
FOR WALLBOARD
PLASTIC
SINGLE-GANG
ELECTRICAL BOX
OR
Page view 0
1 2

Summary of Contents

Page 1 - Instructions

DXS-80WIRELESS CARBON MONOXIDE ALARMInstallation InstructionsPRODUCT DESCRIPTIONThe DXS-80 is a carbon monoxide (CO) alarm with a built-in transmitte

Page 2 - WARNING

Copyright © 2009 Linear LLC 227112 D1.0 WHAT YOU SHOULD KNOW ABOUT COCarbon monoxide (CO) is an insidious poison. It is a colorless, odorless and tas

Comments to this Manuals

No comments